Recycling

Zig-Zag Air Separator

Air separation for light and heavy fractions, selected with the material form, particle condition and upstream/downstream process interfaces.

Contact us →

PRODUCT OVERVIEW

Designed around the production task.

Air separation for light and heavy fractions, selected with the material form, particle condition and upstream/downstream process interfaces.

MATERIAL & PROCESS CONTEXT

Material, process and output context.

Technical configuration is available on request. Please share your material, output target and product specification with the Grace team.

CONFIGURATION ENGINEERING

Engineering air-separation module around the actual material

A recycling system is defined from the actual feedstock and required downstream use, not from a headline model or capacity. Material condition, contamination, safety boundary and each process interface are reviewed together before a project configuration is released.

01

Material definition

Confirm polymer family, material form, incoming size, contamination profile, moisture, labels, metals, non-target fractions and any restricted or hazardous contents before selecting the route.

02

Process-route integration

The selected process interface is after preparation and before the selected separation or collection stage. Each module is balanced with its upstream preparation, downstream handling and the declared target material requirement.

03

Utilities, residue and safety

Water management, residue handling, ventilation, access, guarding and site constraints are defined with the actual material and local operating conditions; they are not assumed from a generic reference line.

04

Project confirmation

The final equipment list, operating window, controls and acceptance criteria are confirmed through project engineering, controlled technical review and the agreed validation plan.

FOR A TECHNICAL PROPOSAL

Information that lets us define the right line.

  • Density difference, size distribution, moisture and impurity split
  • Clear material photos or representative samples, including packaging and contamination condition
  • Required target material, downstream use and any purity, moisture or handling expectations
  • Factory layout, utilities, water-treatment boundary, safety rules and local regulatory requirements
  • Required controls, service access, documentation language and project delivery expectations

This v2 Beta page presents the R&D-signed technical reference for the stated material and process scope. It is not a price, delivery, quality, certification or contractual performance commitment; the final project configuration and acceptance conditions remain subject to controlled engineering review.

TECHNICAL DATA

Representative zig-zag air separator models

ModelPrimary roleApplicable feedstock / conditionCandidate route capacity rangeKey standard configurationSelection boundary
GRZ600Air separationPrepared plastic flakes or light/heavy mixed fractions within the selected routeNo standalone capacity published7.75 kW installed powerAir volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.
GRZ800DAir separationPrepared plastic flakes or light/heavy mixed fractions within the selected routeNo standalone capacity published11.75 kW installed powerAir volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.
GRZ1200Air separationPrepared plastic flakes or light/heavy mixed fractions within the selected routeNo standalone capacity published10.65 kW installed powerAir volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.
GRZ1200LAir separationPrepared plastic flakes or light/heavy mixed fractions within the selected routeNo standalone capacity published13.4 kW installed powerAir volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.

GRZ600

Primary role
Air separation
Applicable feedstock / condition
Prepared plastic flakes or light/heavy mixed fractions within the selected route
Candidate route capacity range
No standalone capacity published
Key standard configuration
7.75 kW installed power
Selection boundary
Air volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.

GRZ800D

Primary role
Air separation
Applicable feedstock / condition
Prepared plastic flakes or light/heavy mixed fractions within the selected route
Candidate route capacity range
No standalone capacity published
Key standard configuration
11.75 kW installed power
Selection boundary
Air volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.

GRZ1200

Primary role
Air separation
Applicable feedstock / condition
Prepared plastic flakes or light/heavy mixed fractions within the selected route
Candidate route capacity range
No standalone capacity published
Key standard configuration
10.65 kW installed power
Selection boundary
Air volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.

GRZ1200L

Primary role
Air separation
Applicable feedstock / condition
Prepared plastic flakes or light/heavy mixed fractions within the selected route
Candidate route capacity range
No standalone capacity published
Key standard configuration
13.4 kW installed power
Selection boundary
Air volume, cut point and actual throughput depend on material density, particle size, moisture and upstream preparation.

The controlled source confirms the listed models and installed power, but does not publish a standalone throughput. Final separation performance is defined with the actual material, density difference, particle-size distribution, moisture condition and process test or project review.

PRODUCT INQUIRY

Discuss this system with Grace.

Share your raw material, product specification, capacity target and project country.

Email info@gracepm.com →